Blower Door, Duct Leakage & Energy Code Testing

Testing and consultation for homeowners and builders in ME and NH.

Efficient Home Services logo

Efficient Home Services provides performance testing and consultation for homeowners, builders and contractors in Southern Maine and Seacoast New Hampshire. Most building codes now require performance testing of HVAC ductwork and building envelope air tightness, and we can help you plan for those tests and pass them.

Blower Door & Envelope Air Leakage Testing

Blower door fan in a doorway for an air leakage test

A blower door test measures how airtight a home’s building envelope is. A fan mounted in an exterior doorway changes the pressure in the house so that air leakage can be measured and the leaks can be located.

For homeowners, it shows where heated and cooled air is escaping. For builders, it verifies envelope air tightness for the tests required by code.

On new construction this is often called a code air test or energy code air leakage test. The house is tested at a set pressure and the result is compared with the maximum air leakage allowed by the energy code your town has adopted.

Duct Leakage Testing: Total & to Outside

Technician running a duct leakage test

Duct leakage testing (Duct Blaster) measures how much air escapes from HVAC ductwork. We can test total leakage or leakage to outdoors, which significantly increases your odds of passing for code.

More detail on our duct leakage testing page.

Energy Code Compliance for New Construction & Additions

Hard hat, blueprints and tools

We are a Certified Third Party Inspector for Residential Energy Code, working with builders and contractors in ME and NH on new homes and additions. We offer testing and consultation to help you meet requirements such as the 2009 or later International Energy Conservation Code (IECC).

By involving us early in planning and construction we can help ensure the systems will pass the tests required by code. See all of our services for contractors.

Our energy code air leakage testing includes the blower door code air test for the building envelope and, where the code calls for it, a duct leakage test, with results you can give your code official.

Blower Door Testing in Maine

Maine’s statewide code, the Maine Uniform Building and Energy Code (MUBEC), adopted the 2021 International Energy Conservation Code (IECC) with Maine amendments, effective April 7, 2025. MUBEC applies statewide, and towns with 4,000 or more residents must enforce it. Smaller towns can choose whether to enforce it, so check with your local code office.

Maine’s air leakage limit

Under the Maine amendments, a new home must be tested for air leakage with a blower door, and the result can’t exceed 3.0 air changes per hour at 50 pascals (3 ACH50) or 0.20 CFM50 per square foot of dwelling unit enclosure area. Maine applies that limit under every compliance path, where the unamended 2021 IECC allows up to 5.0 ACH50 on some paths. Limited exceptions apply to some attached and smaller dwelling units.

How the code air test works

The test is run to ANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at 50 pascals, any time after all penetrations of the building envelope have been sealed. Where the code official requires it, the test must be done by an approved third party, and a written, signed report of the results goes to the code official. The result is also recorded on the energy certificate posted in the home. We are a Certified Third Party Inspector for Residential Energy Code. A test before drywall, while the air barrier is still exposed, makes leaks easier to find and fix before the final test.

New Hampshire

New Hampshire’s state building code uses the 2018 IECC with NH amendments, which set the residential air leakage limit at 5.0 ACH50. Local requirements can vary, so confirm with your code official.

Building in Southern Maine or on Seacoast New Hampshire? See our energy code testing for contractors, call (603) 828-2290 or contact us to schedule a test.

Home Energy Audits

Infrared camera image showing heat loss on a house

For existing homes, testing is part of a complete energy audit. Our energy audits follow BPI Standards and can include blower door testing, duct leakage testing, infrared camera inspections and combustion safety testing. After we have inspected and tested the home we produce a written report complete with costs, estimated savings and prioritized improvements.

Learn more about home energy audits.

BPI Certified

BPI Certified Professional logo

Our Building Performance Institute (BPI) certifications include Energy Auditor, Envelope Professional, Multifamily Energy Auditor, Air Leakage Control Installer and Manufactured Homes. See the full list on our About us / Certifications page.

Blower Door & Duct Leakage Testing FAQ

What is a blower door test?

A blower door test measures how leaky a home is. A calibrated fan is temporarily sealed into an exterior doorway and used to lower the air pressure inside the house, usually to 50 pascals below the outdoors. The amount of air the fan has to move to hold that pressure shows how much air is leaking through the building envelope, reported as CFM50 or ACH50. While the house is under pressure, the leaks can be found with an infrared camera or by feel.

What is a duct leakage test?

A duct leakage test measures how much air escapes from forced-air heating and cooling ducts. The supply and return registers are sealed off, a calibrated fan such as a Duct Blaster is connected to the system, and the ducts are pressurized, typically to 25 pascals. A total leakage test measures all of the leaks in the ductwork. A leakage-to-outside test, run together with a blower door, measures only the air lost to the outdoors.

Who needs a code air leakage test?

Builders and contractors usually need one for new homes, and in some cases additions, when the local energy code requires the building envelope to be tested for air leakage with a blower door. Under the 2021 International Energy Conservation Code (IECC), which Maine’s code is based on, forced-air heating and cooling ducts must also be leak tested. Ducts and air handlers that are entirely inside the building’s thermal envelope are still tested, but to a looser limit: 8.0 instead of 4.0 CFM per 100 square feet of conditioned floor area, measured at 25 pascals. Requirements vary by state, town and code edition, so check with your code official. Involving us early makes it easier to plan for passing the test.

How long does a blower door or duct leakage test take?

For a typical house, a blower door test usually takes about an hour on site, including setup. Adding a duct leakage test adds some time. A full home energy audit, with blower door testing, an infrared inspection and combustion safety testing, takes longer, often a few hours. Larger homes and homes with more than one duct system can take longer. Call us for an estimate for your project.

What areas do you serve?

We are based in Berwick, Maine and serve Southern Maine and Seacoast New Hampshire, including York County towns such as Berwick, Kittery, York, Wells and Sanford, and Seacoast New Hampshire communities such as Portsmouth, Dover and Rochester. See blower door testing in York County, ME and energy audits in Portsmouth, NH. If you are nearby and not sure, give us a call.

After Testing: Duct Sealing & Ventilation

If a duct leakage test shows too much leakage, we can help with duct sealing and retest. For tight homes, we also help with ERV and HRV ventilation so the house gets fresh air without wasting heat.